Homaro Robotics

From ‘the robot says done’ to knowing the task was done right.

Four steps. Using task recordings, available robot data and your acceptance criteria. No changes to your robot's control or safety systems.

1

Write down what done means

Define the expected outcome for each task: what needs to happen, where it needs to happen, and which acceptance criteria must be met. These criteria provide the reference against which Homaro evaluates each execution.

ILLUSTRATIVE TASK SPECIFICATION
# Thresholds are illustrative examples
task: bearing_insert
part: BRG-6204
target: housing B-12, bore 1
accept:
  seat_depth_mm: <= 0.5
  housing_damage: none
  insertion_force_n: <= 60

2

Connect the data you already record

Start with recorded task executions and the robot data you already have.

Not every task requires every sensor. The required evidence depends on what needs to be verified.

Data Homaro uses
Task description and acceptance criteriaEssential
Execution video with timestampsCore V1 input
Task/run identificationNeeded to associate evidence
Robot joint/motion dataImportant
Gripper feedbackDepends on task
Force/torque dataWhen available and relevant
  • Acceptance criteria
  • Execution video
  • Task/run ID
  • Joint/motion data
  • Gripper feedback
  • Force/torque, if available

Homaro

One timeline per run, tied to its task ID and checked against your criteria.

3

Check every run on one clock

Homaro synchronises available video, joint states, gripper events and sensor readings against timestamps and task IDs.

Each signal provides a different piece of evidence. Homaro brings them together to evaluate whether the observed execution meets the defined acceptance criteria.

Task 2208 Insert harness connector J4Simulated example

Swipe to see the full 5 s.

CameraJoint statesGripperForce (N)Expected ≥ 24 NMeasured peak 14 NSeated · 3.6 s0.0 s1.0 s2.0 s3.0 s4.0 s5.0 s

Latch engagement not verified.

Video shows the connector seated. Force peaked at 14 N; a latched insert shows ≥ 24 N.

4

Get a verdict you can check

Pass
Available evidence supports that the acceptance criteria were met.
Fail
Evidence indicates that one or more acceptance criteria were not met.
Inconclusive
Available evidence is insufficient to establish the outcome.

Each result shows the evidence behind it, so your team can review the call.

Task 2215 Bearing insertIllustrative example
  • Seat depth ≤ 0.5 mmFail1.8 mm
  • No housing damagePassFrames 412–436
  • Insertion force ≤ 60 NInconclusiveNo force data

What Homaro never does

  • Takes control of your robot or modifies its safety systems.
  • Requires you to replace your existing robot or controller.
  • Processes data beyond the access and permissions you provide.